Ultra Server - Xeon Scalable
关键特性:


• Virtualization
• Cloud Computing
• High Density Enterprise Server
• Software Defined Storage
1. Dual socket P (LGA 3647) supports Intel® Xeon® Scalable Processors, 3 UPI up to 10.4GT/s
2. Up to 3TB ECC 3DS LRDIMM or RDIMM, up to DDR4-2666MHz; 24 DIMM slots
3. Up to 2 PCI-E 3.0 x8 slots (FH, FL); For 20 NVMe configuration, only 1 PCI-E 3.0 x8 is available For 18 NVMe configuration, 2 PCI-E 3.0 x8 will be available
4. 2x 25G SFP28 Ethernet ports
5. 20 Hot-swap 2.5" 7mm drive bays; up to 20 NVMe (CPU1: 8 NVMe + 2 NVMe/SAS/SATA3 hybrid, CPU2: 10 NVMe); 1 M.2 NVMe port, Optional extra  M.2 NVMe and SATA3 ports
6. 8 Heavy duty fans w/ optimal fan speed control; 2 air shrouds
7. 1600W Redundant Power Supplies Titanium Level (96%)

Product SKUs
SYS-1029UZ-TN20R25M
  • SuperServer 1029UZ-TN20R25M (Black)
 
Motherboard

Super X11DPU-Z+
 
Processor/Cache
CPU
  • Dual Socket P (LGA 3647)
  • Intel® Xeon® Scalable Processors,
    3 UPI up to 10.4GT/s
  • Support CPU TDP 70-205W
Cores
  • Up to 28 Cores with Intel® HT Technology
 
System Memory
Memory Capacity
  • 24 DIMM slots
  • Up to 3TB ECC 3DS LRDIMM, 3TB ECC RDIMM, DDR4 up to 2666MHz
Memory Type
  • 2666/2400/2133MHz ECC DDR4 SDRAM
 
On-Board Devices
Chipset
  • Intel® C621 chipset
SATA
  • SATA3 (6Gbps); RAID 0, 1, 5, 10
Network Connectivity
  • 2 25GbE SFP28 ports via AOC-URN4-M2TS (Mellanox ConnectX-4 Lx EN)
  • Download networking card drivers here
IPMI
  • Support for Intelligent Platform Management Interface v.2.0
  • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
Graphics
  • ASPEED AST2500 BMC
 
Input / Output
NVMe
  • 8 NVMe ports + 2 SAS/SATA3/NVMe Hybrid Ports (from CPU 1)
  • 10 NVMe ports (from CPU 2)
LAN
  • 2 25GbE SFP28 ports
  • 1 RJ45 Dedicated IPMI LAN port
USB
  • 3 USB 3.0 ports
    (2 rear, 1 Type A)
  • 2 USB 2.0 ports
    (front)
Video
  • 1 VGA port
Serial Port
  • 1 Serial header
DOM
  • 2 SuperDOM (Disk on Module) ports
 
System BIOS
BIOS Type
  • AMI 32Mb SPI Flash ROM
 
Management
Software
Power Configurations
  • ACPI Power Management
 
PC Health Monitoring
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory.
  • 4+1 Phase-switching voltage regulator
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
Chassis
Form Factor
  • 1U Rackmount
Model
  • CSE-116UTQ20-R1K62-T
 
Dimensions and Weight
Height
  • 1.7" (43mm)
Width
  • 17.2" (437mm)
Depth
  • 27.8" (706mm)
Gross Weight
  • 48 lbs (21.8 kg)
Available Color
  • Black
 
Front Panel
Buttons
  • Power On/Off button
  • System UID button
LEDs
  • Power LED
  • Hard drive activity LED
  • Network activity LEDs
  • UID LED
 
Expansion Slots
PCI-Express
  • 2 PCI-E 3.0 x8 slots (FH, FL)
    For 20 NVMe configuration, only 1 PCI-E 3.0 x8 is available.
    For 18 NVMe configuration, 2 PCI-E 3.0 x8 will be available. 
    (Both CPUs need to be installed for full access to PCI-E slots and onboard controllers. See manual block diagram and AOC Support for details.)
 
Drive Bays / Storage
Hot-swap
  • 20 Hot-swap 2.5" 7mm drive bays
  • 20 NVMe (CPU1: 8 NVMe + 2 NVMe/SAS/SATA3 hybrid ports, CPU2: 10 NVMe ports)
M.2
  • 1 M.2 NVMe (2240/2260/2280/22110)
  • 1 M.2 SATA3 via optional cable CBL-SAST-0538 (2240/2260/2280/22110)
  • 2 M.2 NVMe via optional add-on card AOC-SLG3-2M2 (2260/2280/22110)
 
System Cooling
Fans
  • 8 Heavy duty fans with optimal fan speed control
Air Shroud
  • 2 Air Shroud
 
Power Supply
1600W Redundant Power Supplies with PMBus
Total Output Power
  • 1000W/1600W
Dimension
(W x H x L)
  • 73.5 x 40 x 203 mm
Input
  • 100-127Vac / 13 - 9A / 50-60Hz
  • 200-240Vac / 10 - 8A / 50-60Hz
+12V
  • Max: 83.3A / Min: 0A (100-127Vac)
  • Max: 133A / Min: 0A (200-240Vac)
12Vsb
  • Max: 2.1A / Min: 0A
Output Type
  • 25 Pairs Gold Finger Connector
Certification Titanium Level96%  UL/cUL/CB/BSMI/CE/CCC
  Titanium Level
  Test Report ]
 
Operating Environment
RoHS
  • RoHS Compliant
Environmental Spec.
  • Operating Temperature: 
       10°C ~ 35°C (50°F ~ 95°F)
  • Non-operating Temperature: 
       -40°C to 60°C (-40°F to 140°F)
  • Operating Relative Humidity: 
       8% to 90% (non-condensing)
  • Non-operating Relative Humidity: 
       5% to 95% (non-condensing)

See Parts List
Parts List - (Items Included)
 
Part Number
Qty
Description
Motherboard / Chassis MBD-X11DPU-Z+ 
CSE-116UTQ20-R1K62-T
1
1
Super X11DPU-Z+ Motherboard
CSE-116UTQ20-R1K62-T
Add-on Card / Module AOC-SLG3-2E4T-P 2 AOC-SLG3-2E4T-P
Add-on Card / Module AOC-SLG3-4E4T-P 1 AOC-SLG3-4E4T-P
Add-on Card / Module AOC-URN4-M2TS-P 1 1U Ultra Riser 2-port 25GbE SFP28, based on Mellanox Connect
Backplane BPN-NVME3-116UN 1 20-port 1U (CSE116U) NVMe direct-attached backplane, support up to 20x 7mm NVMe SSDs, 2 are hybrid ports also support SAS/SATA devices
Cable 1 CBL-CDAT-0674 1 4 Pin to 4 Pin I2C cable, 30cm, 26AWG, 4 wires, pinout 1-1, for vpp header(jnvi2c1),RoHS/REACH
Cable 2 CBL-PWEX-1018 1 BPN PWR,2X4F/GPU-White to 2x2F,P4.2, 12V, 42CM,18AWG, 11A/pin, -25~85C
Cable 3 CBL-PWEX-1019 1 BPN PWR,2X4F/GPU-White to 2x2F,P4.2, 12V, 67CM,18AWG, 11A/pin, -25~85C
Cable 4 CBL-SAST-0818 3 OCuLink v. 1.0,INT,PCIe NVMe SSD, 55CM,34AWG
Cable 5 CBL-SAST-0819 2 OCuLink v 1.0,INT,PCIe NVMe SSD, 65CM,34AWG,RoHS/REACH
Cable 6 CBL-SAST-0820 2 OCuLink v. 1.0,INT,PCIe NVMe SSD, 85CM,34AWG,RoHS/REACH
Cable 7 CBL-SAST-0847 8 OcuLink v 1.0,INT,PCIe NVMe SSD, 76CM,34AWG
Cable 8 CBL-SAST-0974-1 5 OcuLink v 1.0,INT,PCIe NVMe SSD, 37CM,34AWG
Cable 9 CBL-SAST-1015-1 1 MINI SAS-2 SATA (RA),6G,INT,52CM,62CM SB,30AWG,RoHS
Air Shroud MCP-310-11601-0B 1 Mylar air shroud for SC116U (X11 24DIMM, left side)
Riser Card RSC-UMR-8 1 1U Ultra RHS Riser Card with 1 PCIE/SATA Hybrid M.2 &1 PCIE
Riser Card RSC-UN4-88 1 RSC-UN4-88
Heatsink / Retention SNK-P0067PS 2 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism
Power Supply PWS-1K62A-1R 2 AC-DC 1600W, Titanium Level, Redundancy, 1U, DC Output: +12V and +12Vs, 203 x 73.5 x 40 mm, AC Input: 90 - 264 VAC/47-63Hz, PMBus 1.2 with DSP controller,HF,RoHS/REACH
FAN 1 FAN-0101L4 8 40x56,4 Pin PWM,Primary for SC809,111, Sec.for SC816,819,808
Rear Window MCP-240-81915-0N 1 Rear window for SC819U, 119U tool-less chassis (m2TS)

Optional Parts List
  Part Number Qty Description
Add-on card for internal M.2 NVMe AOC-SLG3-2M2 1 Low Profile PCIe x8 add-on card supports 2 M.2 NVMe Modules
Cable for 4x Hybrid NVMe/SATA Drive Bays CBL-SAST-0880 1 MINI SAS(RA-RS EXIT)-4 SATA,INT,55/55/55/55CM,55CM SB,30AWG for optional 4x SATA3
Storage Control Card and Cable for 4x Hybrid NVMe/SAS Drive Bays AOC-S3008L-L8e &
1 CBL-SAST-0948
AOC-S3008L-L8i &
1 CBL-SAST-0948
AOC-S3108L-H8iR &
1 CBL-SAST-0948
1
1
1
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60
Cable for internal M.2 SATA CBL-SAST-0538 1 29cm 30AWG SATA S-RA cable
Storage Control Card and Cable(s) AOC-S3008L-L8e
AOC-S3008L-L8i
AOC-S3108L-H8iR
- Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E
Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60
Network Card(s) AOC-SGP-i2/4
AOC-STGN-i1S/i2S
AOC-STGF-i2S
AOC-STG-i4S
AOC-STG-b4S
AOC-STG-i2T
AOC-STGS-i1/2T
AOC-STG-i4T
AOC-STG-i2
AOC-S25G-m2S
AOC-S40G-i2Q
More
-
-
-
-
-
-
-
-
-
-
-
-
Standard LP, 2/4x GbE RJ45, PCI-E x4, Intel i350
Standard LP, 1/2x 10GbE SFP+, PCI-E x8, Intel 82599EN
Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel XL710-BM2
Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel XL710
Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S
Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540
Standard LP, 1/2x 10GbE RJ45, PCI-E x8, Intel X550
Standard LP, 4x 10GbE RJ45, PCI-E x8, Intel XL710
Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB
Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN
Standard LP 2-port 40GbE controller, Intel Fortville XL710
AOC Compatibility Matrix
CachVault(s) BTR-CV3108-1U1 
BTR-TFM8G-LSICVM02 & BKT-BBU-BRACKET-05

-
CacheVault for Broadcom 3108 with Supercap mounting in 1U 40x56 fan tray 
CacheVault for Broadcom 3108; Supercap mounting bracket for PCI-E location
Hot-swap 3.5" to 2.5" Hard Disk Drive Tray MCP-220-00043-0N - Black hot-swap 3.5" to 2.5" HDD tray
1U Cable Management Arm MCP-290-00152-0N 1 1U Supermicro Cable Management Arm 2nd Gen
TPM security module AOM-TPM-9670V 1 SPI capable TPM 2.0 with Infineon 9670 controller,
Vertical form factor
TPM security module AOM-TPM-9671V 1 SPI capable TPM 1.2 with Infineon 9670 controller,
Vertical form factor
Intel VROC RAID Key AOC-VROCINTMOD
AOC-VROCSTNMOD
AOC-VROCPREMOD
1
1
1
Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only)
Intel VROC Standard, RAID 0, 1, 10
Intel VROC Premium, RAID 0, 1, 5, 10
Global Services & Support OS4HR3/2/1
OSNBD3/2/1
-
-
3/2/1-year onsite 24x7x4 service
3/2/1-year onsite NBD service
Software SFT-OOB-LIC 1 OOB Management Package (per node license)
Software SFT-DCMS-Single 1 DataCenter Management Package (per node license)

联系我们

北京富扬维鑫科技有限公司(北京市海淀区志新东路8号五层)

  电话(010)51286188 传真 (010)82375099

信息在本文件如有变更,恕不另行通知。其他产品和公司本文提及的商标或注册商标属于各自的公司或商标持有人。